Technical data

LOADING CHAMBER CAPACITY 40 L
LOADING CHAMBER USEFUL DIMENSIONS (W x D x H) 320 x 247 x 520 mm
LOADING CAPACITY (containers) 1 x TESABOX 40
or 2 x TESABOX 20
Total Cycle Time (NF X30-503-1 standard) (1) 30 to 35 min
Total Cycle Time  in working conditions (2) 30 to 35 min
Loading Capacity (kg/cycle) Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste
3,2 to 4,8 kg/cycle
Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid Waste
4,8 to 8 kg/cycle
Treatment Capacity (kg /h) (3) Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste
4 to 6 kg/h
Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid Waste
6 to 10 kg/h
MAX QUANTITY OF LIQUID RECOMMENDED PER CYCLE (4) 12 L
EXTERNAL DIMENSIONS (W x D x H) 1300 x 895 x 1450 mm
Net weight 580 kg (1278.6 lbs.)
Loading chamber Stainless steel with PTFE coating
Treatment chamber AISI 304L stainless steel
Steam generator AISI 304L stainless steel (chamber) & Highly corrosion-resistant Hastelloy®
Water softener Built-in
Water booster pump and air compressor Built-in
Waste Shredder Structure: AISI 304L stainless steel & Blades: High-strength steel
Piping Stainless steel/PTFE flexible hosing
Chassis Painted steel
Bodywork Composite material/Painted steel
Cycle traceability – Through printout Built-in
USB port Built-in

(1) 30-35min for test loads as per NF X30-503-1 standard.
(2) Cycle times may vary based on the type of materials, waste density, humidity, quantity of liquids, etc. For loads with high liquid content, cycle time can be longer. Up to 50min depending on the waste density.
(3) Based on an average cycle time of 45min. (40 min. of cycle + 5 min. unloading/loading time).
(4) Quantity of liquids allowed might vary depending on application (urine bags, blood bags, food testing bags, …).
All the data given in this catalog are non-binding and given as a guide only. Treatment capacities and cycle times are given as mere examples and may vary depending on the type of waste, installation conditions, operator’s availability and skills.

Use Data.

Water Needs Softened or drinking quality water
Water Consumption Approx. 10 liters/cycle
Electricity Needs 380–400V III N, 50 Hz/60 Hz, 15 kW
Electricity Consumption 4 to 5 kWh/cycle
Drain 32mm ø internal (heat-resistant)  (1.2″)
Steam / Compressed air Produced by the integrated generator and compressor; no external connection required